Metrologic IS3480 QuantumE Uživatelská příručka Strana 1

Procházejte online nebo si stáhněte Uživatelská příručka pro Motor Metrologic IS3480 QuantumE. Metrologic IS3480 QuantumE User`s guide Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - IS3480 QuantumE

IS3480 QuantumEScan Engine User’s Guide

Strany 2 - Patents

6 INSTALLATION RS232, RS232 TTL, Light Pen or Laser Emulation 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink

Strany 3 - TABLE OF CONTENTS

7 INSTALLATION RS485  1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the MVC cable into the 10-pin socket on the IS3480. 3.

Strany 4

8 INSTALLATION Keyboard Wedge 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on th

Strany 5 - INTRODUCTION

9 INSTALLATION Stand-Alone Keyboard 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socke

Strany 6

10 INSTALLATION Low Speed USB (Integrated) 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the USB PowerLink cable into the 10-

Strany 7

11 INSTALLATION Notes for Laser Emulation IS3480-104 Only The IS3480-104 leaves the factory with the Laser Emulation Mode enabled. If the Reca

Strany 8

12 SCANNER OPERATION Configurable Primary and Secondary Scan Pattern Modes There are two configurable scan pattern modes available with the IS34

Strany 9

13 SCANNER OPERATION Configurable Button Functions SECONDARY SCAN PATTERN BUTTON CLICK MODE WITH CODEGATE ENABLED For illustration purposes the un

Strany 10 - INSTALLATION

14 SCANNER OPERATION Configurable Button Functions SECONDARY SCAN PATTERN BUTTON CLICK MODE WITH CODEGATE DISABLED For illustration purposes the

Strany 11

15 SCANNER OPERATION Configurable Button Functions SECONDARY SCAN PATTERN BUTTON HOLD MODE WITH CODEGATE ENABLED For illustration purposes the un

Strany 12

Disclaimer Honeywell International Inc. (“HII”) reserves the right to make changes in specifications and other information contained in this document

Strany 13

16 SCANNER OPERATION Configurable Button Functions SECONDARY SCAN PATTERN BUTTON HOLD MODE WITH CODEGATE DISABLED For illustration purposes the u

Strany 14

17 SCANNER OPERATION Sweet Spot Mode The sweet spot mode is used to determine where the maximum read rate area or “sweet spot” is located for a

Strany 15

18 SCANNER OPERATION Audible Indicators When the IS3480 is in operation, it can provide audible feedback. These sounds indicate the status of the

Strany 16 - SCANNER OPERATION

19 SCANNER OPERATION Visual Indicators There are four LEDs located on the top of the IS3480. When the scanner is on, the flashing or constant il

Strany 17

20 SCANNER OPERATION Failure Mode Indicators Flashing Blue and One Razzberry Tone This indicates that the scanner has experienced a laser subsy

Strany 18

21 SCANNER OPERATION Depth of Field Specifications* Normal Scan Zone Specifications are based on a 0.33 mm (13 mil) bar code. Figure 9. Norma

Strany 19

22 SCANNER OPERATION Depth of Field Specifications* Reduced Scan Zone Specifications are based on a 0.33 mm (13 mil) bar code. Figure 10. Redu

Strany 20

23 SCANNER OPERATION Depth of Field by Bar Code Element Width* Normal Scan Zone MINIMUM BAR CODE ELEMENT WIDTH A B C D E F mm .13 .15

Strany 21

24 SCANNER OPERATION Depth of Field by Bar Code Element Width* Reduced Scan Zone MINIMUM BAR CODE ELEMENT WIDTH A B C D E F mm .13 .1

Strany 22

25 SCANNER OPERATION IR Activation Range* QuantumE’s default power save mode† is Laser OFF. This power save mode turns the laser off after a co

Strany 23

ii TABLE OF CONTENTS Introduction Product Overview ... 1

Strany 24

26 TROUBLESHOOTING GUIDE The following guide is for reference purposes only. Contact a Honeywell representative to preserve the limited warranty

Strany 25

27 TROUBLESHOOTING GUIDE Symptoms Possible Cause(s) Solution All Interfaces The unit scans a bar code, but locks up after the first scan (the whi

Strany 26

28 TROUBLESHOOTING GUIDE Symptoms Possible Cause(s) Solution RS232 Only The unit powers up OK and scans OK but does not communicate properly to t

Strany 27

29 DESIGN SPECIFICATIONS IS3480 Operational Normal Depth of Field: 25 mm - 280 mm (1"- 11") 0.33 mm (13 mil) bar code Reduced Dept

Strany 28

30 DESIGN SPECIFICATIONS IS3480 Mechanical Width: 63 mm (2.48") Depth: 50 mm (1.97") Height: 68 mm (2.68") Weight: 6 oz (170 g

Strany 29

31 APPLICATIONS AND PROTOCOLS The model number on each scanner includes the scanner number and factory default communications protocol. SCANNER V

Strany 30 - TROUBLESHOOTING GUIDE

32 CONFIGURATION MODES The IS3480 Series scanner has three modes of configuration. • Bar Codes The IS3480 can be configured by scanning the bar c

Strany 31

33 UPGRADING THE FIRMWARE The IS3480 is part of Honeywell's line of scanners with flash upgradeable firmware. The upgrade process requires, a

Strany 32

34 DEFAULT SETTINGS - COMMUNICATION PARAMETERS Many functions of the scanner can be "configured" - that is enabled or disabled. The sca

Strany 33 - DESIGN SPECIFICATIONS

35 DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER DEFAULT USB RS232* OR RS232 TTL LIGHT PEN RS485 KBW LASER EMULATION Expanded ID “]e0” *

Strany 34

iii TABLE OF CONTENTS IR Activation Range ... 25 Troubleshooti

Strany 35 - APPLICATIONS AND PROTOCOLS

36 DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER DEFAULT USB RS232* OR RS232 TTL LIGHT PEN RS485 KBW LASER EMULATION Transmit UPC-A Che

Strany 36 - CONFIGURATION MODES

37 DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER DEFAULT USB RS232* OR RS232 TTL LIGHT PEN RS485 KBW LASER EMULATION Nixdorf ID  

Strany 37 - UPGRADING THE FIRMWARE

38 DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER DEFAULT USB RS232* OR RS232 TTL LIGHT PEN RS485KBW  LASER EMULATION Supplements are not

Strany 38 - Host applications

39 SCANNER AND CABLE TERMINATIONS Scanner Pinout Connections The IS3480 scanner interfaces terminate to a 10-pin modular socket. The serial numbe

Strany 39

40 SCANNER AND CABLE TERMINATIONS Figure 15. IS3480-104 RS232, RS232 TTL, or Laser Emulation Pin Function 1 Ground 2 RS232 Transmit Output 3 RS2

Strany 40

41 SCANNER AND CABLE TERMINATIONS Figure 16. Figure 17. Zero Insertion Force Connector (ZIF), 6-pin Utility Connector Pin Function 1 Aux +5V:

Strany 41

42 SCANNER AND CABLE TERMINATIONS Cable Connector Configurations (Host End) “Standard” PowerLink Cable 53-53000x-3 coiled or 59-59000x-3 straight

Strany 42

43 SCANNER AND CABLE TERMINATIONS Cable Connector Configurations (Host End) Keyboard Wedge PowerLink Cable 59-59002x-3 Pin Function 5-Pin DIN,

Strany 43 - Scanner Pinout Connections

44 REGULATORY COMPLIANCE Safety ITE Equipment IEC 60950-1: Second Edition EN 60950-1: Second Edition Laser Laser Class 1: IEC 60825-1: Second Ed

Strany 44 - Figure 15

45 REGULATORY COMPLIANCE EMC Emissions FCC Part 15, ICES-003, CISPR 22, EN 55022 Immunity CISPR 24, EN 55024 NOTE: Immunity performance is not

Strany 45 - Figure 17

1 INTRODUCTION QuantumE is a miniature, omni-directional scanning engine with optional single-line scanning capability. The self-contained device

Strany 46

46 REGULATORY COMPLIANCE EMC Changes or modifications not expressly approved by the party responsible for compliance could void the user’s autho

Strany 47

47 LIMITED WARRANTY Honeywell International Inc. ("HII") warrants its products and optional accessories to be free from defects in mater

Strany 48 - REGULATORY COMPLIANCE

48 LIMITED WARRANTY All provisions of this Limited Warranty are separate and severable, which means that if any provision is held invalid and unen

Strany 49

49 INDEX A AC ... 2, 6–10 Accessories ... 2, 3 Adapter ...

Strany 50

50 INDEX M Maintenance ... 3 Manual... 2, 18, 31 MetroSelect ...

Strany 51 - LIMITED WARRANTY

51 CUSTOMER SUPPORT Technical Assistance If you need assistance installing or troubleshooting your device, please contact us by using one of the

Strany 52

Honeywell Scanning & Mobility 9680 Old Bailes Road Fort Mill, SC 29707 www.honeywellaidc.com 00-02026 Rev K 6/12

Strany 53

2 INTRODUCTION Scanner and Accessories BASIC KIT COMPONENTS Part No. Description IS3480 QuantumE Scanner 00-02026 IS3480 User’s Guide * 00-02407

Strany 54

3 INTRODUCTION Scanner and Accessories OPTIONAL ACCESSORIES Part No. Description 59-59002x-3 Keyboard Wedge PowerLink cable 59-59020x-3 Stand

Strany 55 - CUSTOMER SUPPORT

4 INTRODUCTION Scanner Components Figure 1a. Scanner Components ITEM NO. DESCRIPTION 1 Utility Connector Located Under Rubber Seal The rubber

Strany 56

5 INTRODUCTION Caution and Serial Number Labels Figure 2. Caution To maintain compliance with applicable standards, all circuits connected

Komentáře k této Příručce