Metrologic Hand-Held Scanner Uživatelská příručka Strana 1

Procházejte online nebo si stáhněte Uživatelská příručka pro Čtečky čárových kódů Metrologic Hand-Held Scanner. Metrologic Hand-Held Scanner User`s guide Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - Installation and User’s Guide

MS9500 Voyager™ SeriesSingle-Line Hand-Held Laser ScannerInstallation and User’s Guide

Strany 2 - Locations

5Disconnecting PowerLink Cables from the ScannerBefore removing the cable from the scanner, Metrologic recommendsthat the power on the host system is

Strany 3 - January 2000

6How to Use CodeGate – MS9540 Only• Auto triggeractivatesthe laser• Place thelaser line onthe bar code• Press theCodeGatebutton totransmit thedata123T

Strany 4 - Table of Contents

7Assembling the StandKit #46-46055 Contains:a. Stand (mlpn 36-00343) Qty 1b. Apron (mlpn 50-50440) Qty 1c. Screw, M3 x 6 mm long (mlpn 18-18670) Q

Strany 5 - Table of Contents (continued)

8Assembling the Stand (continued)Stand Option 2: Hard-mounted to countertopStep 1Drill four #39 holes in the countertop.Step 2Secure the base (mlpn 3

Strany 6 - Introduction

9Scanner Parts*This feature is not available on the MS9520Green, Yellow and Red LEDsOutput WindowStandStand ApronCable ConnectionCodeGate Button*

Strany 7 - Scanner and Accessories

10Audible IndicatorsWhen the Voyager is in operation, it provides audible feedback. Thesesounds indicate the status of the scanner. Eight settings a

Strany 8 - Quick Start

11This is a failure indicator. Refer to “Failure Modes”on page 13.

Strany 9

12Visual IndicatorsThere are three LED indicators (green, red and yellow) located on thehead of the MS9500. When the scanner is on, the flashing or st

Strany 10

13Visual Indicators (continued)Alternating Flashing of Green and RedThis indicates the scanner is program mode. A razzberrytone indicates that an inva

Strany 11 - Two Modes of Operation

14Failure ModesFlashing Green and one Razzberry ToneThis indicates the scanner has experienced a laser sub-system failure. Return the unit for repair

Strany 12 - Assembling the Stand

iiLocationsUSA Corporate Headquarters EuropeMetrologic Instruments, Inc. Metrologic Instruments GmbH90 Coles Road Dornierstrasse 2Blackwood, NJ 08012-

Strany 13

15Programming ModesThe MS9500 Voyager has 3 modes of programming.Bar Codes: Voyager can be configured by scanning the bar codeslocated in the METROSEL

Strany 14 - Scanner Parts

16Programming Modes (continued)4. During programming, the motor and laser remain active. YOUCANNOT SCAN ANY BAR CODES WHILE IN PROGRAM MODE.5. There

Strany 15 - Audible Indicators

17Programming Modes (continued)EXAMPLE #3: The following example shows the events that occur when aninvalid bar code is sent. This sample will load t

Strany 16

18Upgrading the Flash Rom FirmwareThe Meteor program is a functional component of Metrologic’s new lineof flash-based scanners. This program allows th

Strany 17 - Visual Indicators

19LabelsEach scanner has a label on the back of the unit. This label has themodel number, date of manufacture, serial number, CE and cautioninformati

Strany 18 - Visual Indicators (continued)

20Depth of Field2.5” [64 mm]5.0” [127 mm]6.5” [165 mm]8.0” [203 mm]2.0” [51 mm]0.0” [0 mm]1.0” [25.4 mm]10.0” [254 mm]2.5” [64 mm]Scan Width atABEGHJW

Strany 19 - Failure Modes

21IR Activation2.5” [64 mm]Scan Width atFaceShort Range IR4.0” ± 1.0”[102 mm ±25.4mm]0.0” [0 mm]Long Range IR11.0” ± 2.0”[229 mm ± 51mm]Distance From

Strany 20 - Programming Modes

22MaintenanceSmudges and dirt can interfere with the proper scanning of a bar code.Therefore, the output window will need occasional cleaning.1. Spray

Strany 21 - Programming Modes (continued)

23Applications and ProtocolsThe model number on each scanner includes the scanner number andfactory default communications protocol.ScannerVersionIden

Strany 22

24Trouble Shooting GuideThe following guide is for reference purposes only. Contact a Metrologicrepresentative at 1-800-ID-Metro or 1-800-436-3876 to

Strany 23

iiiJanuary 2000

Strany 24 - AVOID EXPOSURE

25Troubleshooting Guide (continued)Symptoms Possible Causes SolutionThe unit powersup, but does notscan/or beepBeeper disabled. No toneselectedEnable

Strany 25 - Depth of Field

26Troubleshooting Guide (continued)Symptoms Possible Causes SolutionScanner beeps atsome bar codesand NOT for othersof the same barcode symbologyThe p

Strany 26 - IR Activation

27Troubleshooting Guide (continued)Symptoms Possible Causes SolutionThe unit scans thebar code but thereis no dataConfiguration is not correctMake sur

Strany 27 - Maintenance

28Troubleshooting Guide (continued)Symptoms Possible Causes SolutionPower-up OK andscans OK ,butdoes notcommunicateproperly to the hostCom port at the

Strany 28 - Applications and Protocols

29RS-232 Demonstration ProgramIf an RS-232 scanner is not communicating with your IBMcompatible PC, key in the following BASIC program to test thatthe

Strany 29 - Trouble Shooting Guide

30Appendix A – Design SpecificationsOperationalLight Source Visible Laser Diode 650 nm ± 10 nmLaser Power 0.96 mW (peak)Depth of Scan Field 0 mm – 203

Strany 30

31Appendix B – Default SettingsMany functions of the scanner can be “programmed” – that is, enabledor disabled. The scanner is shipped from the facto

Strany 31

32Appendix B – Default Settings (continued)PARAMETERDEFAULTOCIA RS-232LIGHTPENIBM46XXKBWMod 43 Check on Code39     MSI-Plessy 10/10 CheckDigit 

Strany 32

33Appendix B – Default Settings (continued)PARAMETERDEFAULTOCIA RS-232LIGHTPENIBM46XXKBWSame symbol rescantimeout 750 msecs     Same symbol resca

Strany 33

34Appendix B – Default Settings (continued)PARAMETER DEFAULT OCIA RS-232LIGHTPENIBM46XX KBWTransmit Sanyo IDCharacters  Nixdorf ID  LRC Enabled 

Strany 34 - RS-232 Demonstration Program

ivTable of ContentsIntroduction... 1Scanner and Accessories.

Strany 35

35Appendix B – Default Settings (continued)PARAMETER DEFAULT OCIA RS-232LIGHTPENIBM46XX KBW100 msec to FindSupplementProgrammable in 100msec steps (ma

Strany 36 - Appendix B – Default Settings

36110 Appendix CThe MS9520 and MS9540 scannerinterfaces terminate to a 10-pinmodular jack. The serial # labelindicates the interface enabledwhen the s

Strany 37

37Appendix C (continued)Cable Connector Configurations“Standard” PowerLink cableMLPN 530009-pin D-type female connector to the PCPin Function1 Shield

Strany 38

38Appendix C (continued)Cable Connector ConfigurationThe PowerLink cable is terminated with a 5-pin DIN female connector onone end, and a 6-pin mini D

Strany 39 - DEFAULT OCIA RS-232

39Appendix D – Warranty and DisclaimerLimited WarrantyThe MS9500 scanners are manufactured by Metrologic at its Blackwood, New Jersey, USAfacility. Th

Strany 40

40Appendix E - NoticesNoticeThis equipment has been tested and found to comply with the limits for a ClassB digital device, pursuant to Part 15 of the

Strany 41 - Appendix C

41Appendix E – Notices (continued)AchtungDie Verwendung anderer als der hier beschriebenen Steuerungen, Einstellungenoder Verfahren kann eine lebensge

Strany 42 - Appendix C (continued)

42Appendix FPatentsPatent InformationThis METROLOGIC product may be covered by one or more of thefollowing US Patents:US Patent No. 4,958,984; 5,081,

Strany 43 - Appendix C (continued)

43AddendumAddendum 1:1If the optional power adapter available through Metrologic does not power thebar code scanner, the scanner will receive power fr

Strany 44 - Limited Warranty

44IndexAAC input/outlet 4Accessories iii, 2Approvals 18Audible iii, 10Autodiscriminates 29BBar Code 1, 3, 10, 11, 12, 14,15 16 21, 24, 25, 26, 2

Strany 45 - Appendix E - Notices

vTable of Contents (continued)Appendix A Design Specifications... 29Appendix

Strany 46 - Attenzione

45IndexRRazzberry tone 10, 12, 13, 31Red LED 3, 10, 11, 17, 24Repair 13, 38RMA 38RS-232 22, 27, 28, 30, 31, 3233, 34, 35, 36SSELV 2Service ii, 38S

Strany 47 - Appendix F

1IntroductionThe Voyager™ MS9500 Series single-line hand-held scanners includeboth the MS9520 and MS9540.The Voyager MS9540 features Metrologic’s pate

Strany 48 - Addendum

2Scanner and AccessoriesThe following list of parts may or may not be included in the MS9500 kit.• Voyager MS9520 Single-Line Laser Scanner, orVoyager

Strany 49

3Quick Start1. Connect the 10-pin RJ45 male connector into the jack on theVoyager. You will hear a ‘click’ when the connection is made.2. Connect the

Strany 50

4Installing the Scanner to the Host System1. Turn off the host system.2. Make the proper PowerLink cable connections to the scanner.Please refer to th

Komentáře k této Příručce