Metrologic MS3580 Uživatelská příručka

Procházejte online nebo si stáhněte Uživatelská příručka pro Čtečky čárových kódů Metrologic MS3580. Metrologic MS3580 User`s guide Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - QuantumT

QuantumT ™Omnidirectional Laser Scanner 3580 User’s Guide

Strany 2 - Patents

6 INTRODUCTION Mounting Specifications and Stand Assembly Pedestal Stand Figure 4. Pedestal Stand Assembly Optional Flex Stand Figure 5. Ass

Strany 3 - TABLE OF CONTENTS

7 INTRODUCTION Mounting Specifications and Stand Assembly Optional Flex Stand Figure 6. Mounting Hole Detail for the Flex Stand Base Plate (Opti

Strany 4

8 INSTALLATION RS232, RS232 TTL, Light Pen or Laser Emulation 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink

Strany 5

9 INSTALLATION RS485 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the MVC cable into the 10-pin socket on the MS3580. 3.

Strany 6

10 INSTALLATION Keyboard Wedge 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on t

Strany 7

11 INSTALLATION Stand-Alone Keyboard 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin sock

Strany 8

12 INSTALLATION USB 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the USB cable into the 10-pin socket on the MS3580. 3. Pl

Strany 9

13 SCANNER OPERATION Configurable Primary and Single Line Scan Pattern Modes There are two configurable scan pattern modes available with the MS

Strany 10 - INTRODUCTION

14 SCANNER OPERATION Configurable Button Functions SINGLE SCAN PATTERN BUTTON CLICK MODE WITH CODEGATE ENABLED For illustration purposes the unit’

Strany 11

15 SCANNER OPERATION Configurable Button Functions SINGLE SCAN PATTERN BUTTON CLICK MODE WITH CODEGATE DISABLED For illustration purposes the uni

Strany 12 - INSTALLATION

Disclaimer Honeywell International Inc. (“HII”) reserves the right to make changes in specifications and other information contained in this document

Strany 13

16 SCANNER OPERATION Configurable Button Functions SINGLE SCAN PATTERN BUTTON HOLD MODE WITH CODEGATE ENABLED For illustration purposes the unit’

Strany 14

17 SCANNER OPERATION Configurable Button Functions 5. To scan and transmit additional bar codes, repeat steps 2 through 4. 6. The primary sca

Strany 15

18 SCANNER OPERATION Configurable Button Functions SECONDARY SCAN PATTERN BUTTON HOLD MODE WITH CODEGATE DISABLED For illustration purposes the u

Strany 16

19 SCANNER OPERATION Audible Indicators When the MS3580 is in operation, it provides audible feedback to indicate the status of the scanner. Eigh

Strany 17 - SCANNER OPERATION

20 SCANNER OPERATION Visual Indicators The QuantumT is equipped with a blue and white LED that indicates the scanner’s state and the status of th

Strany 18

21 SCANNER OPERATION Failure Mode Indicators Flashing Blue and One Razzberry Tone This indicates that the scanner has experienced a laser subsy

Strany 19

22 SCANNER OPERATION Depth of Field Specifications* Normal Scan Zone Specifications are based on a 0.33 mm (13 mil) bar code. Figure 14. MS35

Strany 20

23 SCANNER OPERATION Depth of Field Specifications* Reduced Scan Zone Specifications are based on a 0.33 mm (13 mil) bar code. Figure 15. MS35

Strany 21

24 SCANNER OPERATION Depth of Field by Bar Code Element Width* Normal Scan Zone MINIMUM BAR CODE ELEMENT WIDTH A B C D E F mm .13 .15

Strany 22

25 SCANNER OPERATION Depth of Field by Bar Code Element Width* Reduced Scan Zone MINIMUM BAR CODE ELEMENT WIDTH A B C D E F mm .13 .1

Strany 23

ii TABLE OF CONTENTS Introduction Product Overview ... 1 S

Strany 24

26 SCANNER OPERATION IR Activation Range* QuantumT‘s default power save mode† is Laser OFF. This power save mode turns the laser off after a co

Strany 25

27 TROUBLESHOOTING GUIDE The following guide is for reference purposes only. Contact a Honeywell representative to preserve the limited warranty

Strany 26

28 TROUBLESHOOTING GUIDE Symptoms Possible Cause(s) Solution All Interfaces The unit scans a bar code, but locks up after the first scan (the whi

Strany 27

29 TROUBLESHOOTING GUIDE Symptoms Possible Cause(s) Solution All Interfaces During power up the unit beeps 3 times. There is a non-volatile RAM f

Strany 28

30 TROUBLESHOOTING GUIDE Symptoms Possible Cause(s) Solution RS232 Only The host is receiving data but the data does not look correct. The scanne

Strany 29

31 DESIGN SPECIFICATIONS MS3580 Operational Normal Depth of Field: 19 mm - 273 mm (.75"- 10.75") 0.33 mm (13 mil) bar code Reduced

Strany 30

32 DESIGN SPECIFICATIONS MS3580 Mechanical Width: 63 mm (2.48") Depth: 50 mm (1.97") Height: 68 mm (2.68") Weight: 6 oz (170 g

Strany 31 - TROUBLESHOOTING GUIDE

33 APPLICATIONS AND PROTOCOLS The model number on each scanner includes the scanner number and factory default communications protocol. SCANNER V

Strany 32

34 DEFAULT SETTINGS - COMMUNICATION PARAMETERS Many functions of the scanner can be "configured" - that is enabled or disabled. The sca

Strany 33

35 DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER DEFAULT USB RS232* OR RS232 TTL LIGHT PEN RS485 KBW LASER EMULATION Expanded ID “]e0” *

Strany 34

iii TABLE OF CONTENTS Design Specifications ... 31 Application

Strany 35 - DESIGN SPECIFICATIONS

36 DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER DEFAULT USB RS232* OR RS232 TTL LIGHT PEN RS485 KBW LASER EMULATION Transmit UPC-A Che

Strany 36

37 DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER DEFAULT USB RS232* OR RS232 TTL LIGHT PEN RS485 KBW LASER EMULATION Nixdorf ID  

Strany 37 - APPLICATIONS AND PROTOCOLS

38 DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER DEFAULT USB RS232* OR RS232 TTL LIGHT PEN RS485 KBW LASER EMULATION Supplements are not

Strany 38

39 CONFIGURATION MODES The MS3580 Series scanner has three modes of configuration. • Bar Codes The MS3580 can be configured by scanning the bar c

Strany 39

40 UPGRADING THE FIRMWARE The MS3580 is part of Honeywell’s line of scanners with flash upgradeable firmware. The upgrade process requires a new f

Strany 40

41 SCANNER AND CABLE TERMINATIONS Scanner Pinout Connections The MS3580 scanner interfaces terminate to a 10-pin modular socket. The serial # lab

Strany 41

42 SCANNER AND CABLE TERMINATIONS MS3580-11 RS485 Pin Function 1 Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 RTS Output

Strany 42

43 SCANNER AND CABLE TERMINATIONS Cable Connector Configurations (Host End) “Standard” PowerLink Cable MLPN 59-59000x -3 straight Pin Function

Strany 43 - CONFIGURATION MODES

44 SCANNER AND CABLE TERMINATIONS Cable Connector Configurations (Host End) Keyboard Wedge PowerLink Cable 54-54002x -3 Pin Function 5-Pin DIN,

Strany 44 - UPGRADING THE FIRMWARE

45 REGULATORY COMPLIANCE Safety ITE Equipment IEC 60950-1: Second Edition EN 60950-1: Second Edition Laser Laser Class 1: IEC 60825-1: Second Edi

Strany 45 - Scanner Pinout Connections

1 INTRODUCTION The QuantumT ™ is a hands-free, omnidirectional bar code scanner with optional single-line scanning capabilities. It utilizes th

Strany 46

46 REGULATORY COMPLIANCE EMC Emissions FCC Part 15, ICES-003, CISPR 22, EN 55022 Immunity CISPR 24, EN 55024 NOTE: Immunity performance is not

Strany 47 - MLPN 54-54020

47 REGULATORY COMPLIANCE EMC Changes or modifications not expressly approved by the party responsible for compliance could void the user’s author

Strany 48

48 LIMITED WARRANTY Honeywell International Inc. ("HII") warrants its products and optional accessories to be free from defects in mater

Strany 49 - REGULATORY COMPLIANCE

49 LIMITED WARRANTY All provisions of this Limited Warranty are separate and severable, which means that if any provision is held invalid and unen

Strany 50

50 INDEX A AC ... 2, 8–12 Accessories ... 2, 3 Adapter ...

Strany 51

51 INDEX M Maintenance ... 3 Manual... 2, 19, 33 Meteor ...

Strany 52 - LIMITED WARRANTY

52 CUSTOMER SUPPORT Technical Assistance If you need assistance installing or troubleshooting your device, please contact us by using one of the m

Strany 56 - CUSTOMER SUPPORT

2 INTRODUCTION Scanner and Accessories BASIC KIT COMPONENTS Part No. Description MS3580 QuantumT Omni \ Single-Line Scanner 00-02026 QuantumT

Strany 57

Honeywell Scanning & Mobility 9680 Old Bailes Road Fort Mill, SC 29707 www.honeywellaidc.com 00-05090 Rev F 6/12

Strany 58

3 INTRODUCTION Scanner and Accessories OPTIONAL ACCESSORIES Part No. Description 54-54002x-3 Keyboard Wedge PowerLink Cable straight cord, short

Strany 59

4 INTRODUCTION Scanner Components Figure 1. Scanner Components ITEM NO. DESCRIPTION 1 Red Output Window (Laser Aperture) 2 Pin Hole for Cable

Strany 60

5 INTRODUCTION Caution and Serial Number Labels Figure 2. Labeling Example Caution To maintain compliance with applicable standards, all ci

Komentáře k této Příručce

Žádné komentáře